Vector Lab代理VECTASHIELD® Vibrance™ Antifade Mounting Medium with DAPI

Vector Labs代理,欢迎访问Vector Labs官网或者咨询我们获取相关Vector Labs产品信息以及报价。
Vector Labs 公司是世界著名的生物学检测试剂公司,七十年代其在全球首推的生物素-亲和素系统引领了生物学检测方法的重大革命,该系统被普遍视为目前最灵敏、最可靠与最有效的染色系统,并被广泛应用于免疫组织化学、免疫电镜、原位杂交与凝集素化学中。该系统仍在不断地发展,以满足广大研究人员的各种不同要求。Vector 公司还是世界上凝集素产品的主要供应商,并提供大量的新产品,如酶底物、神经元示踪剂及蛋白质、糖类与核酸的标记、分离与检测试剂。

VECTASHIELD® Vibrance™ Antifade Mounting Medium with DAPI

H-1800

SKU Unit Size Price Qty
H-1800-2 2 ml

H-1800-10 10 ml

To request a quote for products:

  1. Click “Contact Us” in the header bar above;
  2. Click “Customer Service”;
  3. Complete the form and provide the following information in the “Comments” section: note you would like a quote, item number (SKU) and quantity;
  4. Click “Submit”.

VECTASHIELD® Vibrance™ Antifade Mounting Medium with DAPI

Description
Specifications
Documents
Product FAQs
Related Products
Technical Information

Description

VECTASHIELD Vibrance Antifade Mounting Media are completely new formulations of curing (hard setting) antifade mounting media for immunofluorescence applications. These newest additions to our VECTASHIELD portfolio were developed with customer feedback to improve on parameters such as ease of use and retention of specific staining intensity over time. VECTASHIELD Vibrance Antifade Mounting Media are new tools to help investigators see more and do more with each experiment.

VECTASHIELD Vibrance offers you:

  • Superior antifade/anti-photobleaching properties across the spectrum
  • Compatibility with commonly used fluorophores
  • View sections one hour after mounting
  • No tone or autofluorescent background, even after curing
  • Room temperature storage of slides with extended archiving time
  • Minimal bubble formation, even after several weeks storage
  • Curing formulations with choice of counterstain (DAPI) or no counterstain
  • 12 month product expiration date

Plus the same features that have made the VECTASHIELD brand successful:

  • Ideal refractive index
  • Easy to use
  • Ready to use, requires no warming
  • No sealing of coverslips required (curing formulations)

Specifications

More Information
Unit Size 2 ml, 10 ml
Applications Immunofluorescence, In situ hybridization, Cellular Imaging
Concentration 0.9 µg/ml
Recommended Storage Refrigerate
Mounting Aqueous (Hardening)
Antifade Yes
Counterstain DAPI (blue fluorescence)
Cellular Stain Nucleus

Documents

  • Safety Data Sheet
  • User Guide
  • VECTASHIELD Fluorochrome Compatibility
  • VECTASHIELD Vibrance Brochure
  • In Situ Hybridization Detection Protocol
  • Download CoA
  • Datasheet

Product FAQs

How quickly can I view sections after mounting with VECTASHIELD® Vibrance (catalog # H-1700)? Is it recommended to wait one hour?

Sections can be viewed immediately after mounting with VECTASHIELD® Vibrance, but one hour is recommended for optimal signal intensity.

How long does it take for the VECTASHIELD® Vibrance to cure?

With adequate removal of excess buffer, the VECTASHIELD Vibrance will cure enough by one hour to hold the coverslip in place. Complete curing takes about 4 – 24 hours at room temperature.

How long can I store slides mounted with the VECTASHIELD Vibrance?

After mounting with VECTASHIELD Vibrance, slides can be stored at room temperature for several months without media retraction, bubble formation, or loss of signal intensity. We have not seen any difference between room temperature or storage at 4 degrees C.

Does VECTASHIELD contain glycerol?

All of the VECTASHIELD formats we currently offer which includes regular non-setting VECTASHIELD, PLUS, HardSet and Vibrance formulations each contain a percentage of glycerol.

Do I need to dehydrate the tissue sections before applying VECTASHIELD?

No form of tissue dehydration (e.g. air drying or ethanol exposure) is required nor recommended when applying VECTASHIELD. From our experience, the most optimal antifade actions of VECTASHIELD are obtained when the preparation is removed from the final buffer/water rinse, kept slightly wet/moist and then coverslipped with a small volume (25-50 uL) of VECTASHIELD.

Do I need to seal the perimeter of the coverslip after I apply VECTASHIELD?

That depends upon how long you wish to retain the slides and which VECTASHIELD formulation you are using. If you are using one of our non-setting VECTASHIELD products such as H-1000/H-1200 or H-1900/H-2000, then we suggest sealing the coverslip with plastic sealant or nail polish if you intend to keep the slides beyond a day or so. If you are using one of our setting/curing formulations such as VECTASHIELD HardSet or Vibrance, then in most cases when using thin cut (<10 um) tissue sections or cell monolayers, no sealing of the coverslip is requuired.

Related Products

VECTASHIELD® Vibrance™ Antifade Mounting Medium with DAPI

VECTASHIELD® Vibrance™ Antifade Mounting Medium Catalog #: H-1700

VECTASHIELD® Vibrance™ Antifade Mounting Medium with DAPI

VECTASHIELD® PLUS Antifade Mounting Medium Catalog #: H-1900

VECTASHIELD® Vibrance™ Antifade Mounting Medium with DAPI

VECTASHIELD® PLUS Antifade Mounting Medium with DAPI Catalog #: H-2000

VECTASHIELD® Vibrance™ Antifade Mounting Medium with DAPI

VECTASHIELD® Antifade Mounting Medium Catalog #: H-1000-10

VECTASHIELD® Vibrance™ Antifade Mounting Medium with DAPI

VECTASHIELD® Antifade Mounting Medium with DAPI Catalog #: H-1200-10

VECTASHIELD® Vibrance™ Antifade Mounting Medium with DAPI

VECTASHIELD® Antifade Mounting Medium with Propidium Iodide (PI) Catalog #: H-1300-10

VECTASHIELD® Vibrance™ Antifade Mounting Medium with DAPI

VECTASHIELD® HardSet™ Antifade Mounting Medium Catalog #: H-1400-10

VECTASHIELD® Vibrance™ Antifade Mounting Medium with DAPI

VECTASHIELD® HardSet™ Antifade Mounting Medium with DAPI Catalog #: H-1500-10

VECTASHIELD® Vibrance™ Antifade Mounting Medium with DAPI

VECTASHIELD® HardSet™ Antifade Mounting Medium with Phalloidin Catalog #: H-1600-10

Technical Information

VECTASHIELD Vibrance - A Brilliant Solution for Fluorescent Signal Retention!

Publications:

  • Jarrin, S. et al. 2020. Differential Role of Anterior Cingulate Cortical Glutamatergic Neurons in Pain-Related Aversion Learning and Nociceptive Behaviors in Male and Female Rats. Frontiers in Behavioral Neuroscience. doi: 10.3389/fnbeh.2020.00139
  • Ixmatlahua, D. et al. 2020. Neuronal Glutamatergic Network Electrically Wired with Silent but Activatable Gap Junctions. The Journal of Neuroscience. doi: 10.1523/JNEUROSCI.2590-19.2020
  • Ghinassi, B. et al. 2020. Immunohistochemical Results of Soft Tissues around a New Implant Healing-Abutment Surface: A Human Study. Journal of Clinical Medicine. doi: 10.3390/jcm9041009
  • Mendoza-Torreblanca, J.G. et al. 2019. Analysis of Differential Expression of Synaptic Vesicle Protein 2A in the Adult Rat Brain. Neuroscience. doi: 10.1016/j.neuroscience.2019.09.004.
  • Leskelä, S. et al. 2019. C9orf72 Proteins Regulate Autophagy and Undergo Autophagosomal or Proteasomal Degradation in a Cell Type-Dependent Manner. Cells. doi: 10.3390/cells8101233
  • Castillo-Martin, M. et al. 2019. Transformed Bone Marrow Cells Generate Neoplasms of Distinct Histogenesis. a Murine Model of Cancer Transplantation. Stem Cell Research. doi: /10.1016/j.scr.2019.101637
  • Wong, W. et al. 2019. The exercise cytokine interleukin 15 rescues slow wound healing in aged mice. Journal of Biological Chemistry. doi: 10.1074/jbc.RA119.010740
  • Sharma, N. et al. 2019. Pharmacological inhibition of Notch signaling regresses pre-established abdominal aortic aneurysm. Scientific Reports. doi: 10.1038/s41598-019-49682-0

VECTASHIELD® Vibrance™ Antifade Mounting Medium with DAPI

VECTASHIELD Vibrance Antifade Properties

VECTASHIELD Vibrance has outstanding antifade properties, acoss the spectrum - even under far-red wavelengths - and they are compatible with most commercially available fluorophores.

VECTASHIELD® Vibrance™ Antifade Mounting Medium with DAPI

Viewable in as Little as One Hour After Mounting - No Need to Wait 24 Hours

Competitor workflows for immunofluorescence recommend that slides be viewed 24 hours after mounting. VECTASHIELD Vibrance Mounting Media, however, allow same-day viewing. Accelerate discovery without sacrificing signal intensity or retention.

VECTASHIELD® Vibrance™ Antifade Mounting Medium with DAPI

Improved retention of fluorescence with VECTASHIELD Vibrance Mounting Medium. Serial sections of human colon tissue (FFPE) stained for cytokeratin (mouse primary antibody AE1/AE3) and detected with fluorescein conjugated horse anti-mouse IgG secondary antibody (FI-2000). One hour after mounting with either VECTASHIELD Vibrance (top row) or a competitor mounting medium (bottom row), the sections were imaged at the intervals indicated. Note retention of fluorescent signal for section mounted with VECTASHIELD Vibrance Mounting Medium.

Extended Archiving of Mounted Sections at Room Temperature

Archiving fluorescently stained sections at room temperature often leads to signal reduction and dessication of the specimen. Slides mounted with VECTASHIELD Vibrance Medium, however, can be stored for weeks at ambient temperature, in standard slide boxes, with no loss of specific signal intensity or specimen integrity. The stabilizing effect of VECTASHIELD Vibrance Mounting Medium provides greater flexibility for imaging and storing fluorescently stained samples.

VECTASHIELD® Vibrance™ Antifade Mounting Medium with DAPI

Archiving fluorescently stained sections at room temperature often leads to signal reduction and dessication of the specimen. Slides mounted with VECTASHIELD Vibrance Medium, however, can be stored for weeks at ambient temperature, in standard slide boxes, with no loss of specific signal intensity or specimen integrity. The stabilizing effect of VECTASHIELD Vibrance Mounting Medium provides greater flexibility for imaging and storing fluorescently stained samples.

With No Specimen Obscuring Retraction or Bubble Formation

Another problem commonly observed in immunoflourescence staining is the formation of bubbles over time, under the coverslip, or the shrinking (retraction) of the media. This phenomenon detracts from the overall quality of the sections and can obscure specific staining. The unique formulation of VECTASHIELD Vibrance Mounting Medium provides a uniform sheet of medium under the coverslip, with essentially no bubble formation or retraction—even after many weeks of storage at room temperature.

VECTASHIELD® Vibrance™ Antifade Mounting Medium with DAPI

Serial sections of human colon tissue (FFPE) stained for cytokeratin (AE1/AE3, mouse primary) followed by Alexa Fluor™ 488 anti-mouse IgG secondary antibody. Sections were mounted with either VECTASHIELD Vibrance Mounting Medium (H-1700, left image) or competitor mounting medium (right image) stored at room temperature for two weeks, and then imaged.

Note the absence of bubbles and background in green spectrum in left image (VECTASHIELD Vibrance Mounting Medium) compared with right image, after two weeks at room temperature.

Summary of VECTASHIELD Vibrance Advantages Over Competitor Mounting Media

VECTASHIELD® Vibrance™ Antifade Mounting Medium with DAPI

Home All Products What's New VECTASHIELD Antifade Mounting Media (IF) VECTASHIELD® Vibrance™ Antifade Mounting Medium with DAPI